Ideal Logic System IE fault L06
False flame lockout / flame on before gas valve on
Gas boilerWhat it means
Boiler detects flame signal before the gas valve has been energised, indicating a false flame detection or wiring/electrode fault.
Likely causes
- Internal boiler wiring routing/integrity fault
- Deteriorated electrode
- Low gas pressure
- Gas valve wiring/PCB fault
- Faulty gas valve
- Faulty spark generator
- Faulty electrode
- Blocked condensate/trap
Where to start
- Restart the boiler and check if boiler works OK
- Check routing and integrity of internal boiler wiring
- Check condition of Electrode and replace if deteriorated
The full answer, free
- 9 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 51), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Ideal manual for the Logic System IE. Check the model on the data plate before you order parts.
Other Ideal Logic System IE fault codes
- F02Flame loss
- F04Flow thermistor fault
- F05Return thermistor fault
- F0DLow water flow / low water pressure
- F0UFlow/return differential greater than 50°C
- F10Spark generator fault
- F12Pump rotor blocked
- F13Pump fault
- F15Pump fault
- F16Gas valve fault
- F17Pump fault
- F2Flame loss
- F3Fan fault
- F4Control/no flow thermistor fault
- F5Return thermistor fault
- F6Outside sensor fault
- F8PCB unconfigured/faulty or gas valve short circuit
- F9PCB unconfigured/faulty or gas valve short circuit
- FDNo water flow
- FNFlame loss
- FUDifferential greater than 50°C
- L02Ignition lockout after 5 attempts
- L04Flow thermistor fault
- L05Return thermistor fault