Ideal Logic System IE fault L2
Ignition lockout after 5 failed attempts
Gas boilerWhat it means
Boiler fails to light after 5 ignition attempts and locks out, displaying fault code L2 on the two-digit display.
Likely causes
- Insufficient gas pressure at boiler inlet
- No 24Vdc supply at gas valve
- Faulty gas valve
- Faulty spark generator or harness
- Faulty ignition electrode or harness
- Faulty detection electrode or harness
- Blocked condensate pipe
- Incorrectly installed flue
- Ignition failure
- Failed ignition sequence
- Gas supply or ignition fault
Where to start
- Restart boiler - does it ignite for a short time and then extinguish? If NO, check gas pressure at boiler inlet (>18 mbar). If NO, check gas supply and rectify fault.
- If gas pressure YES, check if 24Vdc supply is available at the Gas Valve. If NO, check wiring connection from gas valve to PCB for continuity; if OK, replace the PCB.
- If 24Vdc YES, unplug gas valve and check resistance between outside pins is 4KΩ (±2). If NO, replace Gas Valve.
The full answer, free
- 8 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 36), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Ideal manual for the Logic System IE. Check the model on the data plate before you order parts.
Other Ideal Logic System IE fault codes
- F02Flame loss
- F04Flow thermistor fault
- F05Return thermistor fault
- F0DLow water flow / low water pressure
- F0UFlow/return differential greater than 50°C
- F10Spark generator fault
- F12Pump rotor blocked
- F13Pump fault
- F15Pump fault
- F16Gas valve fault
- F17Pump fault
- F2Flame loss
- F3Fan fault
- F4Control/no flow thermistor fault
- F5Return thermistor fault
- F6Outside sensor fault
- F8PCB unconfigured/faulty or gas valve short circuit
- F9PCB unconfigured/faulty or gas valve short circuit
- FDNo water flow
- FNFlame loss
- FUDifferential greater than 50°C
- L02Ignition lockout after 5 attempts
- L04Flow thermistor fault
- L05Return thermistor fault