Midea R32 M thermal Arctic Mono fault EC

Balance tank sensor Tbt2 error

Heat pump

What it means

Balance tank sensor Tbt2 error (serial number 13). Displayed on user interface and refrigerant system main PCB.

Likely causes

  1. Sensor Tbt2 disconnected, sensor malfunction, wiring break, PCB connection issue
  2. Sensor Tbt2 fault
  3. Sensor wiring fault
  4. Main board fuse damaged/blown
  5. Hydronic box main PCB fault
  6. Damaged cables between hydronic box main PCB and outdoor unit main PCB
  7. Outdoor unit main PCB fault
  8. Incorrect or abnormal input power supply (N or L)
  9. Sensor not connected properly
  10. Sensor short-circuited
  11. Sensor resistance inconsistent with characteristics table
  12. Pressure sensor failure
  13. High pressure side blockage
  14. Air side heat exchanger, fan or air outlet dirt/blockage
  15. Water side heat exchanger, water piping, circulator pump or water flow switch dirt/blockage
  16. Insufficient refrigerant caused by refrigerant leakage
  17. Low pressure side blocked by crushed or bent pipe, blocked EXV, or dirty filter
  18. Poor air side heat exchanger heat exchange in heating or DHW mode
  19. Insufficient water flow rate in cooling mode
  20. Outdoor main PCB fault (last resort)

Where to start

  1. Identify sensor type based on fault code
  2. Locate corresponding port on refrigerant system main PCB for that model
  3. Check connection at identified port

The full answer, free

  • 51 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 66), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Midea manual for the R32 M thermal Arctic Mono. Check the model on the data plate before you order parts.

Other Midea R32 M thermal Arctic Mono fault codes