Vaillant aroTHERM fault F.729

Compressor outlet temperature too low

Heat pump

What it means

The compressor outlet temperature is lower than 0 °C for more than 10 minutes or the compressor outlet temperature is lower than -10 °C even though the heat pump is in the operating characteristics.

Likely causes

  1. Compressor outlet temperature lower than 0 °C for more than 10 minutes
  2. Compressor outlet temperature lower than -10 °C even though heat pump is in operating characteristics
  3. Low ambient/outdoor temperature causing heating flow temperature to drop
  4. Low outdoor ambient temperature
  5. Low heating flow temperature at outdoor unit
  6. Heating flow temperature of outdoor unit below 4°C
  7. System control failure
  8. Power cut
  9. Defective compressor
  10. Negative outdoor temperatures Heat pump fault Power cut Defective compressor
  11. Heating flow temperature below 4 °C

Where to start

  1. Checking the high-pressure sensor
  2. Checking that the EEV is working correctly
  3. Check the condenser outlet temperature sensor (subcooling)

The full answer, free

  • 30 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 34), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Vaillant manual for the aroTHERM. Check the model on the data plate before you order parts.