Grundfos STP 2 fault 2
Pompa çalışıyor fakat su basmıyor (positive displacement pumps)
Shower pumpWhat it means
Pump runs but does not deliver water on positive pressure pumps.
Likely causes
- İzolasyon vanaları kapalıdır (Isolation valves closed)
- Filtreler tıkalı (Filters blocked)
- Undersized pipework
- Pipes routed under floor causing air traps
- Other outlets fitted in inlet pipes
- Shared (non-dedicated) hot/cold supplies
- Blanked-off pipes
- Restrictions in flexible hoses
- Unsecured pipework
- Debris ingress into pump causing blockage or damage if strainer omitted
Where to start
- Check pipe diameter is 22 mm to and from pump
- Check expansion pipe from cylinder rises to prevent trapped air
- Check outlet pipe to shower valve rises where possible
The full answer, free
- 29 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 28), right under the answer
Safety: Isolate power and water, and prove dead before you open or test the pump.
From the Grundfos manual for the STP 2. Check the model on the data plate before you order parts.
Other Grundfos STP 2 fault codes
- 1Pompa çalıştırılamıyor (positive displacement pumps)
- 10Hortum bağlantısında sızıntı var (universal head pumps)
- 1AThe pump fails to start (power supply switched off)
- 1BThe pump fails to start (fuses blown)
- 1CThe pump fails to start (thermal protection tripped)
- 1DThe pump fails to start (non-vertical outlet ports)
- 1EThe pump fails to start (insufficient water flow)
- 2FThe pump runs but delivers no water (isolating valves closed)
- 2GThe pump runs but delivers no water (strainers blocked)
- 3Duştan gelen debi düşüyor (positive displacement pumps)
- 3AThe flow from the shower drops (strainers blocked)
- 4Pompa sürekli olarak çalışıyor (positive displacement pumps)
- 4CThe pump runs continuously (float stuck in flow switch)
- 4DThe pump runs continuously (flow switch or reed switch faulty/incorrectly set)
- 5Pompada darbe görülüyor (positive displacement pumps)
- 5AThe pump pulses (other taps causing momentary start)
- 6Su sıcaklığı sabit değil veya pompa gürültülü çalışıyor (positive displacement pumps)
- 7Pompa gürültülü çalışıyor (positive displacement pumps)
- 7ANoisy pump (vibration through mounting surface)
- 8Hortum bağlantısında sızıntı var (positive displacement pumps)
- 8AHose connection leaking (loose hose connection)
- 9Pompa gürültülü çalışıyor (universal head pumps)