Grundfos STP 2 fault 4D

The pump runs continuously (flow switch or reed switch faulty/incorrectly set)

Shower pump

What it means

Continuous pump running due to a faulty or incorrectly set flow switch or reed switch.

Likely causes

  1. Flow switch or reed switch faulty or incorrectly set
  2. Entrapped air causing airlocks in supply pipe
  3. Air not thoroughly purged from system
  4. Air trapped in pump
  5. Blocked strainers common on initial pump installation or new buildings due to jointing compounds, tapes, flux and debris flushed through system
  6. Leak causing loss of tank air pressure
  7. Low flow rates from cistern filling causing frequent pump cycling
  8. Pipes routed under floor causing air traps
  9. Solder joint heat damaging plastic pump components
  10. Air pockets from incorrectly routed pipework
  11. Additional outlet fittings on inlet pipework causing incorrect flow switch operation
  12. Debris ingress into pump causing blockage or damage if strainer omitted

Where to start

  1. Test flow switch/reed switch operation
  2. Inspect for airlocks in supply pipe
  3. Purge all air from system

The full answer, free

  • 29 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 14), right under the answer

Safety: Isolate power and water, and prove dead before you open or test the pump.

From the Grundfos manual for the STP 2. Check the model on the data plate before you order parts.