Ideal Logic Air fault 7

No heat pump starts exceeded

Heat pump

What it means

The number of heat pump start attempts has exceeded the allowed limit.

Likely causes

  1. Repeated failed start attempts
  2. Underlying fault preventing successful start
  3. Dwelling room temperature dropped to ≤8°C
  4. Dwelling ambient temperature at or below 8°C
  5. Ambient air temperature at or below 1°C

Where to start

  1. Identify 'Alarm' symbol to indicate a plant error
  2. Identify 'Maintenance/Special operations' symbol for maintenance message or special operation feedback
  3. Identify 'Event' symbol for event message from the plant

The full answer, free

  • 20 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 103), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.