Vokera Pinnacle System fault E040
Low water pressure (definitive fault/lockout)
Gas boilerWhat it means
Definitive/permanent lockout fault due to persistent low water pressure, occurring when E041 is not resolved within 10 minutes.
Likely causes
- Unresolved low water pressure condition
- Persistent system leak
- Failure to top up pressure after E041 warning
- System pressure outside optimal range of 1.0-1.5 bar
Where to start
- Check system pressure
- Investigate for leaks if pressure drop is frequent
The full answer, free
- How to put it right, step by step
- The manual page for this fault (page 6), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Vokera manual for the Pinnacle System. Check the model on the data plate before you order parts.
Other Vokera Pinnacle System fault codes
- COMAppliance PCB communication lost
- E010Maximum number of ignition attempts
- E011Parasitic flame
- E021Gas valve control malfunction
- E034Chimney obstruction in preventilation
- E035Blockage obstruction flue gas low power
- E036Blockage obstruction flue gas high power
- E050Smoke obstruction error low power
- E051Smoke obstruction error high power
- E075Valve opening limit reached
- E077Absence of communication with low temperature thermostat
- E091Primary heat-exchanger cleaning fault
- E099Reset attempts exhausted