Grant Aerona R290 fault E01
Connection fault between wiring centre and heat pump
Heat pumpWhat it means
Displayed on the touch screen display during initial switch on, indicating a communication or connection issue between the wiring centre and the heat pump.
Likely causes
- Faulty or loose connection between wiring centre and heat pump
- Wire disconnection or wiring error between the heat pump, wiring centre and touch screen display
- Fuse on the hydraulic module PCB may have failed
- Fuse on the Smart Controller wiring centre PCB may have failed
Where to start
- Check wiring between heat pump, wiring centre and touch screen display
- Check fuse on hydraulic module PCB
- Check fuse on Smart Controller wiring centre PCB
The full answer, free
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 52), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Grant manual for the Aerona R290. Check the model on the data plate before you order parts.
Other Grant Aerona R290 fault codes
- 1Pump over-voltage protection
- 2Pump under-voltage protection
- 3Pump over-current protection
- 4Pump light-load protection
- 5Pump phase loss protection
- 6Pump block protection
- 7Pump over-temperature protection
- E10Communication failure between hydraulic PCB and refrigerant PCB
- E13Discharge pressure sensor fault
- E15DC bus voltage is too low
- E16DC bus voltage is too high
- E17AC current protection (input current)
- E18IPM module is abnormal
- E19PFC abnormal
- E20Compressor failed to start
- E21Compressor phase loss
- E22Inverter module reset
- E23Compressor over-current
- E24PFC module temperature is too high
- E25Current detection circuit failure
- E26Out of step
- E27PFC module temperature sensor is abnormal
- E29IPM module temperature is too high
- E30IPM module temperature sensor failure